Ask Latest Price
Brand Name:GINRI
Model Number:RD6-W
Certification:CE,CCC
Price:
Payment Terms:L/C, T/T, Western Union,Paypal
Supply Ability:20000Pcs per month
Delivery Time:1-30 days upon order quantity
Company Data
Active Member
Business Type: 86-577-6298-2267
Business Type: Manufacturer
Officials: No.337,Kaichuang Road,Baitawang Industrial Distrit, Beibaixiang Town,Yueqing City,Zhejiang Province,China
Quality: Quality Certifitation Available
Product Details Company Profile
Product Details

Compressors Three Phase Voltage Monitoring Relay RD6-W Digital Setting


Phase and voltage monitoring relay can prevent the badly from unbalance ,so,what's harm when phase unbalance happened


1 . Increase the power loss of the line. In the three-phase four-wire power supply network, when the current passes through the line conductor, power loss will be generated due to the impedance, and the loss is proportional to the square of the passing current. When the low-voltage power grid is powered by a three-phase four-wire system, the three-phase load imbalance is inevitable because of the presence of a single-phase load. When the three-phase load is unbalanced, there is current through the neutral line. This not only has a loss of phase, but also a loss of the neutral line, which increases the loss of the power line.


2 . Increase the power loss of distribution transformers. The distribution transformer is the main power supply equipment for the low-voltage power grid. When it is operated under unbalanced three-phase load conditions, the distribution transformer loss will increase. Because the power loss of the distribution varies with the degree of load imbalance.


3 . Reduction in distribution and output. In distribution transformer design, the winding structure is designed according to load balancing operating conditions. The winding performance is basically the same and the rated capacities of the phases are equal. The maximum allowable output of the transformer is limited by the rated capacity of each phase. If the distribution transformer is operated under a three-phase load unbalanced condition, the light-loaded phase has a surplus capacity, thereby reducing the output of the distribution transformer. The degree of reduction in its output is related to the degree of unbalance of the three-phase load. The greater the unbalanced three-phase load, the more reduction in distribution transformer output. For this reason, the distribution transformer operates when the three-phase load is unbalanced, the output capacity thereof cannot reach the rated value, the standby capacity thereof is correspondingly reduced, and the overload capacity is also reduced. If the distribution transformer is operated under overload conditions, it is easy to cause the distribution to generate heat, and even if it is severe, the distribution transformer may be damaged.


4 . The distribution transformer produces a zero-sequence current. The distribution transformer operates under the three-phase load unbalanced condition and will generate a zero-sequence current, which will change with the degree of unbalance of the three-phase load. The greater the unbalance, the greater the zero-sequence current. If there is a zero-sequence current in the transformer during operation, zero-sequence flux will be generated in the iron core. (There is no zero-sequence current on the high-pressure side.) This forces the zero-sequence flux to only pass through the tank wall and the steel member as a passage. The steel member has a low permeability, and hysteresis and eddy currents are generated when the zero-sequence current passes through the steel member. Loss, so that the temperature distribution of the steel component of the transformer rises or even heat. Transformer winding insulation may also accelerate aging due to overheating, resulting in reduced equipment life. At the same time, the presence of zero-sequence current will increase the loss of distribution transformer.


5 . Affect the safe operation of electrical equipment. The distribution transformer is designed according to

the three-phase load balancing operating conditions. The resistance, leakage reactance and excitation impedance of each phase winding are basically the same. When the distribution transformer operates in three-phase load balancing, the three-phase currents are basically the same, and the voltage drop of each phase in the distribution transformer is also basically the same, then the three-phase voltage of the distribution transformer output is also balanced.
If the distribution transformer operates when the three-phase load is unbalanced, the output current of each phase is not equal, and the internal three-phase voltage drop of the distribution transformer is not equal, which will inevitably lead to unbalanced three-phase distribution output voltage. At the same time, the distribution transformer runs when the three-phase load is unbalanced, the three-phase output current is not the same, and the neutral line will have the current through. As a result, the neutral line produces an impedance drop, which causes a shift in the neutral point, resulting in a change in the phase voltage of each phase. The one-phase voltage with a heavy load decreases, while the one-phase voltage with a light load increases. When the voltage is unbalanced, power is supplied to the user's electrical device that is likely to cause a high-voltage one-phase connection, and the user's electrical device that is connected to a low-voltage one may not be used. Therefore, when the three-phase load is unbalanced, it will seriously jeopardize the safe operation of the electrical equipment.


6 . Motor efficiency is reduced. The distribution transformer operates under unbalanced three-phase load conditions and will cause unbalanced three-phase output voltage. Because the unbalanced voltage has three voltage components of positive sequence, negative sequence, and zero sequence, when the unbalanced voltage is input to the motor, the negative sequence voltage generates a rotating magnetic field and the rotating magnetic field generated by the positive sequence voltage acts as a brake. effect. However, because the positive sequence magnetic field is much stronger than the negative sequence magnetic field, the motor still rotates in the direction of the positive sequence magnetic field. However, due to the braking effect of the negative sequence magnetic field, the output power of the motor must be reduced, resulting in a decrease in motor efficiency. At the same time, the temperature rise and reactive power loss of the motor will also increase with the unbalance of the three-phase voltage. Therefore, the motor operates under three-phase voltage imbalance, which is very uneconomical and unsafe.


♦ Features

--Built-in LCD and keypad afford a precise,digital setting

-- Three-phase monitoring of phase sequence, phase loss, over- and undervoltage

-- Adjustable over- and undervoltage threshold

-- Independent adjustable delay time for phase sequence, phase loss, overvoltage, undervoltage

-- Powered by the measuring circuit

-- 1 C/O & 1NC contacts

-- with Timing, counting and faulure recording


♦ Protective Functions

-- Phase sequence

-- Phase loss

-- Overvoltage

-- Undervoltage

-- Timing

-- Counting
-- Faulure recording

♦ Typical Applications

Pumps • Fans

Blowers • Motors

Compressors


♦ Approvals

CE • CCC


♦ Technical data

TypeRD6-W
Measuring circuitL1,L2,L3
Rated voltage380VAC ,50/60Hz
Monitoring functionsphase sequence, phase loss, overvolatege, undervoltage, timing, counting
Overvoltage setting range380-600V adjustable
Undervoltage setting range100-380V adjustable
Hysteresis1-20V adjustable
Delay time for overvoltage and undervoltage1-20s adjustable
Delay time for phase loss1-20s adjustable
Delay time for phase sequence1-20s adjustable
IndicatorsLCD indicating voltage,current,operation status
Output contacts1 C/O,1NC
Contact capacity6A ,250VAC
Dimensions (H x W x D)80×40×54mm
MountingDIN rail

Compressors Three Phase Voltage Monitoring Relay RD6-W Digital Setting

Company Profile

Wenzhou Ginri Power Automation Co., Ltd.

GINRI POWER AUTOMATION CO.,LTD. is a professional production voltage phase sequence protection device (and name: three-phase power monitor), and PLC output zoom Board, and smart type motor integrated protection device, and industrial parts manufacturers, technology development team in elevator industry, and refrigeration industry, and crane industry, environmental equipment, mechanical NC industry and the industrial following insurance industry, field has more than 10 years practice experience, has development out variety price economic and function excellent of products. CQC product quality system by China Quality Centre (3C) certification and CE certification, products in the manufacturing process in strict accordance with the ISO9001 quality assurance system requirements and professional technical and service support.

Voltage phase-sequence protection for many years (equipment, refrigeration equipment, crane (passenger and goods) elevators, control of DC power supply system (Cabinet) screens, precision air conditioners, room air conditioners, electric hoist, boiler equipment, laser equipment, parking equipment, cranes, compressors) and so on using the run.

PLC output amplifiers (environmental protection equipment, numerical control and automation equipment, automobile, plastic machinery, hydraulic machinery, ceramic foam machinery, woodworking machinery, machinery) and so on using the run.

Years of integrated Intelligent motor protector (power plants, paper mills, steel mills, aluminium plants, cement plants, sewage treatment plants, coal preparation plants, refineries, petrochemical plants), and so on using the run.

Product quality is stable and safe, reliable, and earned a solid market position in the market and a high reputation in the industry, received unanimous recognition and praise of our customers.

Ginri company always adhere to "scientific management as the core, the user needs for the Centre to focus on product quality, meticulous service is sincere," the spirit of enterprise, please call us from all walks of life, thank you!

Send your message to this supplier
*From:
Your email address is incorrect!
*To:

Wenzhou Ginri Power Automation Co., Ltd.

*Subject:
Your subject must be between 10-255 characters!
*Message:
Your message must be between 20-3,000 characters!
Characters Remaining : (0/3000)

You May Like

China Pumps Three Phase Voltage Monitoring Relay , JVM-A Phase Detection Relay 460VAC wholesale

Pumps Three Phase Voltage Monitoring Relay , JVM-A Phase Detection Relay 460VAC

China Phase sequence Three Phase Voltage Monitoring Relay Miniature voltage relay wholesale

Phase sequence Three Phase Voltage Monitoring Relay Miniature voltage relay

China Digital Three Phase Voltage Monitoring Relay Over voltage protector AC380V 6A wholesale

Digital Three Phase Voltage Monitoring Relay Over voltage protector AC380V 6A

China Elevator part Three Phase Voltage Monitoring Relay phase failure protective deivce 380VAC Din rail wholesale

Elevator part Three Phase Voltage Monitoring Relay phase failure protective deivce 380VAC Din rail

China Water Pumps Three Phase Voltage Monitoring Relay 380V protector 1CO  6A contact capacity wholesale

Water Pumps Three Phase Voltage Monitoring Relay 380V protector 1CO 6A contact capacity

China Compressors Used Three Phase Voltage Monitoring Relay 1-25s time delay protector wholesale

Compressors Used Three Phase Voltage Monitoring Relay 1-25s time delay protector

China 6A Three Phase Voltage Monitoring Relay for electric motors voltage control relay wholesale

6A Three Phase Voltage Monitoring Relay for electric motors voltage control relay

China Undervoltage Phase Voltage Monitoring Relay 3 Phase-rotation and phase loss monitoring relay , SPDT 380V wholesale

Undervoltage Phase Voltage Monitoring Relay 3 Phase-rotation and phase loss monitoring relay , SPDT 380V

China Phase failure detection Three Phase Voltage Monitoring Relay 200V-500V , 50/60Hz wholesale

Phase failure detection Three Phase Voltage Monitoring Relay 200V-500V , 50/60Hz

China Phase reversal protector Three Phase Voltage Monitoring Relay 2 CO , 6A wholesale

Phase reversal protector Three Phase Voltage Monitoring Relay 2 CO , 6A

China Reliable  Three Phase Voltage Monitoring Relay of three-phase mains phase failure DIN rail mount wholesale

Reliable Three Phase Voltage Monitoring Relay of three-phase mains phase failure DIN rail mount

Inquiry Cart 0