Over / Under Current Motor Protection Relay 2 C/O Output Contacts With Fault Recording
1. The motor is easier to burn the winding than in the past because of the continuous development of the insulation technology. In the design of the motor, both the increase of output and the reduction of the volume are required, so that the heat capacity of the new type of motor becomes smaller and smaller, and the overload capacity becomes weaker and weaker; Due to the increase in the degree of automation of production, the motor is often required to operate in frequent starting, braking, reversing, and changing loads, which imposes higher requirements on the motor protection device. In addition, the application of the motor is wider. Often working in harsh environments, such as humid, high temperature, dust, corrosion and other occasions. Coupled with the non-standard motor manufacturing, equipment management oversight. All this has caused today's motors to be more easily damaged than in the past, especially overloads, short circuits, phase loss, brooms, etc.
2. The traditional protection device has a poor protection effect. It is the traditional motor protection device that mainly includes fuses and thermal relays. Fuse is mainly used for short-circuit protection. The selection of fuse current needs to consider the starting current of the motor. Therefore, using a fuse alone to protect the motor is not desirable. Thermal relay is the most widely used motor overload protection device, but the thermal relay has low sensitivity, large error, poor stability and unreliable protection. This is precisely the fact that, although many devices have thermal relays installed, the phenomenon of motor damage that affects normal production still prevails. The traditional protection device has not yet been able to realize the motor wear monitoring, rotor eccentric monitoring products.
♦ Features
-- Separate structure,LED part panel mounted and CT part screw fixing
-- Built-in LED and keypad afford a precise,digital setting
-- Three-phase monitoring of short-circuit, locked-rotor,overcurrent, undercurrent, phase loss, phase unbalance,overvoltage,undervoltage
-- Earth fault (should couple with ZCT)
-- Fault recording
-- RS-485 communication port (optional)
-- 4-20 mA analog output (optional)
-- 2 C/O output contacts, one for trip,one for alert
♦ Protective Functions
-- Short-circuit
-- Locked-rotor
-- Overcurrent
-- Undercurrent
-- Phase loss
-- Phase unbalance
-- Overvoltage
-- Undervoltage
-- Earth fault
♦ Typical Applications
• Pumps • Fans
• Blowers • Motors
• Compressors
♦ Technical data
Type | WDZ-1Z | WDZ-1F | WDZ-1F2 |
Rated voltage | 220VAC,380VAC ,50/60Hz | ||
Current range | 1-10A,5-50A,10-100A,20-200A,80-400A,400-600A,600-800A | ||
Protective functions | short-circuit, locked-rotor, overcurrent, undervurrent, phase loss, phase unbalance,overvoltage,undervoltage, earth fault | ||
Optional functions | RS-485 communication port 4-20 mA analog output | ||
Indicators | LED indicating voltage,current,operation status | ||
Output contacts | 1 C/O for trip,1 C/O for alert | ||
Contact capacity | 3A 380VAC | ||
Dimensions (H x W x D) | 118×54×135mm | 101×54×77mm(LED part) | 101×54×77mm(LED part) |
Mounting | screw fixing | LED part panel mounted and CT part screw fixing | LED part panel mounted and CT part rail monting |
Wenzhou Ginri Power Automation Co., Ltd.
GINRI POWER AUTOMATION CO.,LTD. is a professional production voltage phase sequence protection
device (and name: three-phase power monitor), and PLC output zoom
Board, and smart type motor integrated protection device, and
industrial parts manufacturers, technology development team in
elevator industry, and refrigeration industry, and crane industry,
environmental equipment, mechanical NC industry and the industrial
following insurance industry, field has more than 10 years practice
experience, has development out variety price economic and function
excellent of products. CQC product quality system by China Quality
Centre (3C) certification and CE certification, products in the
manufacturing process in strict accordance with the ISO9001 quality
assurance system requirements and professional technical and
service support.
Voltage phase-sequence protection for many years (equipment,
refrigeration equipment, crane (passenger and goods) elevators,
control of DC power supply system (Cabinet) screens, precision air
conditioners, room air conditioners, electric hoist, boiler
equipment, laser equipment, parking equipment, cranes, compressors)
and so on using the run.
PLC output amplifiers (environmental protection equipment,
numerical control and automation equipment, automobile, plastic
machinery, hydraulic machinery, ceramic foam machinery, woodworking
machinery, machinery) and so on using the run.
Years of integrated Intelligent motor protector (power plants,
paper mills, steel mills, aluminium plants, cement plants, sewage
treatment plants, coal preparation plants, refineries,
petrochemical plants), and so on using the run.
Product quality is stable and safe, reliable, and earned a solid
market position in the market and a high reputation in the
industry, received unanimous recognition and praise of our
customers.
Ginri company always adhere to "scientific management as the core,
the user needs for the Centre to focus on product quality,
meticulous service is sincere," the spirit of enterprise, please
call us from all walks of life, thank you!