AC480 - 3546KVA - RL3 Phase Load Bank With 50HZ And High Performance
Introduction
AC480 - 3546KVA 3 Phase Load Bank consist of dry load module and auto control module, test load and output power of generators, the test including setting, fluctuation,transient load/unload,recorded wave analysis,harmonic analysis,testing the static parameter and dynamic parameter
1 System can load power in rated range, measure generator steady-state 3 phase voltage, current, active power, power factor, frequency, and running time, and simulate the generator set, UPS real load working state. Power input using sectional type, energy dissipation type load, forced-air cooling, 3 phase fan decentralized supply air, air-flow is sufficient and low noise.
2 System can work with PC software to realize intelligent operation, automatically finish the parameters testing, and create testing data table, curves and reports that can be printed, reduce a lot of manual operation.
3 The system is a self-developed device used for electricity load testing by Kaixiang Technology. It perfectly combines the dry type load module and measurement and control module, precisely test output power and load performance of kinds of generator set, UPS etc.
Technical specification
System Parameter | |
Rating voltage/frequency | 480V, 3 phase 3 wire, 60HZ 208V, 3 phase 3 wire, 60HZ |
Max Load Power | 480V,3phase 3wire, 60HZ, star coupling “Y” Apparent Power: 3546KVA Resistive Load: 2836kW Inductive Load: 2128KVAR 208V,3phase 3wire, 60HZ, delta coupling “△” Apparent Power: 2000KVA Resistive Load: 1600kW Inductive Load: 1200KVAR |
Load Resolution | 208V,3phase 3wire, 60HZ, delta coupling “△” Resistive load: 0.1,0.2,0.2,0.5,1,2,2,5,10,10,20,50,100,7*200kW Inductive load: 0.1,0.2,0.2,0.5,1,2,2,5,10,10,20,50,100,5*200kvar 480V,3phase 3wire, 60HZ, star coupling “Y” Resistive load: 0.18,0.36,0.36,0.9,1.8,3.6,3.6,9,18,18,36,90,180,7*360kW Inductive load: 0.18,0.36,0.36,0.9,1.8,3.6,3.6,9,18,18,36,90,180,5*360kvar |
Power Factor | 0.8(lag) |
Load Tolerance (each step) | ±5% |
Load Tolerance (overall) | ±3% |
Fan &Control Voltage | External AC 3 phase 4 line, 380V/50Hz |
Wire Connection | Load bank input——Copper bar (star coupling ”Y”) Control power input——Connector-bar |
Communication Interface | RS485,RS232 |
Insulation | F |
Max Protection Grade | IP54 |
Duty Cycle | Continuous |
Cooling | Forced air cooling, by Axial Fan; horizontal inlet air, vertical exhaust cooling |
Enclosure | Container type,with a ladder, air inlet and outlet with mesh enclosure and protection door |
Internal Lighting | Adequate internal lighting will be provided |
Transportation | Hoisting, there are lifting lug in top of casing |
Color | Grey RAL7035 or as required |
Dimensions | 6058mm×2438mm×2896mm(L×W×H) |
Operating Environment Parameter | |
Workplace | Outdoor |
Ambient Temperature | -10℃~+50℃ |
Relative Humidity | ≤95% |
Atmospheric Pressure | 86~106kPa |
Brands of Main Components | |
Contactor | Schneider |
Fuse | Miro |
PLC | Siemens |
Alloy Resistor | Kaixiang |
Data Processing Software | Kaixiang |
Step by Step Load: during steady state load, load bank will increase or reduce power so that smoothly transit into target power, avoiding unscheduled transient load/unload. Step value and step interval can be set.
Constant Power Load: automatically adjust to the power when the voltage fluctuation, keep the setting value.
Auto Load: power and time can be set to some stage, process stage test automatically. Allow pause or process next stage during loading.
Manual load: input power and power factor, then will load according to the value.
Preset Load: input the parameter of generator, choice 0%,25%,50%,75%,100%,110%, calculate power value automatically,
Hebei Kaixiang Electrical Technology Co., Ltd
Kaixiang intelligent power detection technology is the Chinese industry leader dedicated to providing load testing and maintenance of all types of power, to avoid accidents and economic losses due to power failure. As a national high-tech enterprises, science and technology to create the industry's first Kaixiang municipal enterprise technology center, with the establishment of China's oldest and largest intelligent power detection equipment R & D center and production base, creating the first brand of Chinese power detection "KAIXIANG Load. "
Kaixiang Technology was established in 1994, long-term focus on smart power detection technology development and application in shipbuilding, petroleum, offshore platforms, data centers, communications, power, military, aviation, research institutes and other areas, and in strict accordance with the ISO9001 international quality standard management system for the design, manufacture and service. The company's core technologies are independent research, has seven patents, 10 software copyrights, two corporate standards.Among them, Kaixiang "smart power marine generators AC load," Science and Technology Department of Hebei Province has been named the international advanced level scientific and technological achievements, the enterprise standard "dry AC load" to upgrade the industry standard by the Ministry of publicity.
Kaixiang Technology specializes in generators Intelligent Test System, HV / MV dry load, intermediate load military, RLC load, RCD nonlinear loads, renewable energy detection, smart grid - the development of micro-Grid testing and manufacturing equipment . Products have been widely used in the Jiangnan Shipyard, Huangpu Shipyard, Hudong Shipyard, CNOOC, Shengli Oilfield, CICC, Taikang Life, China Mobile, CNR, Beijing Electric Power, Beijing Institute of Technology, and other famous enterprises, institutions, but also exports to the United Kingdom, Japan, Korea, Australia, Singapore, Thailand and other overseas markets. Currently, there are over 20,000 units KaiXiang load in a well-functioning home and abroad.
KaiXiang load can be applied in shipbuilding, petroleum, offshore platforms, data centers, communications networks, financial, military, weapons, mobile power station, power plant security, mass transit, aviation, aerospace, renewable energy, smart grid - micro-grid, the instrument switches , research and teaching as well as electric vehicle charging management and other fields. Can provide users with the design, manufacture, installation, commissioning, training, maintenance of full service, as well as OEM, leasing and on-site testing services.
Kaixiang Technology at Keppel Shipyard in 2006 developed a sense of one-2926kVA resistance load is the first high-power marine dry AC load;
2009 was developed by the Huangpu Shipyard AC690V-14700K generators Intelligent Test System was the country's largest marine generator set capacity testing equipment;
2009 Zhejiang company developed high-power high-voltage AC load AC10.5kV-1760kW is China's first direct test of high-power high-voltage generators dry load;
Jiangnan Shipyard in 2010 developed AC390-12088K generators Intelligent Test System is a dry load on marine naval initial application.
Kaixiang technology to "quality-oriented, customer first" purpose, "professionalism, objectivity, innovation, efficiency" as a concept. Through our efforts, aimed at creating more value for users. We sincerely hope to cooperate with all walks of life friends, co-guardian of electrical safety, to make life better!