Hot Sale Snl7 3p Series (MCB) Miniature Circuit Breaker 63A 10ka
GENERAL
SNL7 series high breaking capacity mini circuit breaker is used in AC50/60Hz, rated voltage of 230V
3, 4 poles 400V, rated current to 63A for overload and short-circuit protection as well as for unfrequented switching under normal case.It is used extensively for industry, commercial and household.This product conform to IEC60898 standard.
1.Application:For protecting cables and equipments against overload and short circuit.
2.General rules for choosing MCB.
a.Technical data of the network at the point considered
The earthing systems,short-circuit current at the circuit breaker installation point,which must always be less than the breaking capacity of this device,network normal voltage.
b.There are 3 curvve characteristics for magnetic operation:
B curve (3-5In) protection and control of the circuits against length cables in TN and IT systems.
C curve (5-10In) protection and control of the circuits against overloads and short-circuits; protection for resistive and inductive loads with low inrush current.
D curve (10-14In) protection and control of the circuits against overloads and short-circuits; protection for circuits which supply loads with high inrush current at the circuit closing (LV/LV transformers,breakdown lamps.)
Advantages:
High breaking capacity , all rated current can reach 6KA;
Many kinds of accessories can be chosen, in modularize and
flexibility combine that make the customer install conveniently;
The cover and function parts both are made of inflaming retarding,
bear high temperature and bear impact plastic;
The breaker is applicable to lighting distribution system in
industrial enterprise, commercially district, high-rise building
and dwelling house.
Specifications
Model | SNL7 |
Pole | 1p,2p,3p,4p |
Rated Current(In) | 1,2,4,6,10,16,20,25,32,40,50,63A |
Rated Voltage(Un) | 230/400V |
Rated Frequency | 50/60HZ |
Tripping curve | B,C,D |
Magnetic releases | B curve: between 3and 5 In |
C curve: between 5and 10In | |
D curve: between 10 and 14In | |
Electro-mechanical endurance | over 6000 cycles |
Standard | IEC/EN 60898-1 | ||
Electrical features | Rated current In | A | 1,2,4,6,10,16,20,25,32,40,50,63 |
Poles | P | 1,2,3,4 | |
Rated voltage Ue | V | 230/400 | |
Insulation voltage Ui | V | 500 | |
Rated frequency | Hz | 50/60 | |
Rated breaking capacity | A | 4500,6000 | |
Rated impulse withstand voltage(1.2/50)Uimp | V | 4000 | |
Dielectric test voltage at ind.Freq.for 1 min | Kv | 2 | |
Pollution degree | 2 | ||
Thermo-magnetic release characteristic | B,C,D | ||
Mechanical features | Electrical life | t | 4000 |
Mechanical life | t | 10000 | |
Protection degree | IP20 | ||
Reference temperature for setting of thermal element | ℃ | 30 | |
Ambient temperature (with daily average ≤35℃) | ℃ | -5~+40(Special application please refer to temperature compensation correction) | |
Storage temperature | ℃ | -25~+70 | |
Installation | Terminal connection type | Cable/Pin-type busbar | |
Terminal size top/bottom for cable | mm2 | 25 | |
AWG | 18-3 | ||
Therminal size top/bottom for busbar | mm2 | 25 | |
AWG | 18-3 | ||
Tightening torque | N*m | 2 | |
In-lbs | 18 | ||
Mounting | on DDIN rail EN 60715(35mm)by means of fast clip device | ||
Connection | From top and bottom |
Product Usage:
General rules for choosing MCB,For protecting cables and equipments against overload and short circuit.
a. Technical date of network at the point considered:
The earthing systems,short-circuit current at the circuit breaker installation point ,which must always be less than the breaking capacity of this device,network normal voltage.
b. There are 3 curve characteristics for magnetic operation:
B curve (3-5 ln) protection and control of the circuits against length cables in TN and IT systems.
C curve (5-10 ln) protection and control of the circuits against overloads and short-circuits; protecton for resistive and inductive loads with low inrush current.
D curve (10-20 ln) protection and control of the circuits against overloads and short-circuits; protection for circuits which supply loads with high inrush current at the circuit closing (LV/LV transformers,breakdown lamps)
>
WENZHOU SANTUO ELECTRICAL CO.,LTD.
WENZHOU SANTUO ELECTRICAL Co., Ltd.(Before:YUEQING SHANTUO
ELECTRICAL CO.,LTD.) is one of manufactories that specialize
in manufacturing Circuit Breaker, AC CONTACTOR, Thermall
Relay,Magnetic Starter(DOL),Solid State Relay,Distribution Case, Voltage Regulator is located in Liushi, Wenzhou, China that called " the
Capital of Low Voltage Electronic Products", enjoying convenient
transportation access and a beautiful environment. The products
have passed CE approvals and strictly comply with IEC standards.
The company has advanced detection instruments and strong technical
force with strong research and development capability, product
constantly updated. The products export Europe, Asia, Southern
Amercia, Middle East, Western Africa market.The products have
passed CE certificate. And our Teams have more than 20years
Experience.
If you are interested in any of our products or would like to
discuss a custom order, please feel free to contact us. We are
looking forward to forming successful business relationships with
new clients around the world in the near future.
On the base of guarrantee the quality, we will try our best to
design new model with ourselves patents for the coming years.