Home /

3RT1056-6AF36 Motor Contactor / 185A Power Contactor Up To 250KW

Send your message to this supplier
*From:
Your email address is incorrect!
To:Yueqing Richuang Automation Equipment Co.,Ltd
*Subject:
Your subject must be between 10-255 characters!
*Message:
Your message must be between 20-3,000 characters!
Yes!I would like your verified suppliers matching service!
Buy cheap 3RT1056-6AF36  Motor Contactor / 185A  Power Contactor Up To 250KW from wholesalers
  • Buy cheap 3RT1056-6AF36  Motor Contactor / 185A  Power Contactor Up To 250KW from wholesalers
  • Buy cheap 3RT1056-6AF36  Motor Contactor / 185A  Power Contactor Up To 250KW from wholesalers
  • Buy cheap 3RT1056-6AF36  Motor Contactor / 185A  Power Contactor Up To 250KW from wholesalers
  • Buy cheap 3RT1056-6AF36  Motor Contactor / 185A  Power Contactor Up To 250KW from wholesalers

3RT1056-6AF36 Motor Contactor / 185A Power Contactor Up To 250KW

Ask Latest Price
Brand Name:
Model Number:3RT1056-6AF36 3RT1054 3RT1055
Certification:UL CE
Price:consult for best discount
Payment Terms:T/T, , Western Union,Paypal,, MoneyGram,, L/C
Supply Ability:200 pcs per month
Delivery Time:2-5 days
Company Data
Verified Supplier
Business Type: Manufacturer Distributor/Wholesaler Agent Exporter Trading Company Seller
Officials: Liushi Town,Yueqing City,Zhejiang Province,China
Quality: Quality Certifitation Available
Visit Website
Product Details Company Profile
Product Details


3RT1056-6AF36 Up to 250KW Electrical Contactors 185A Power Contactor For Switching Motor

Power contactor, AC-3 185 A, 90 kW / 400 V AC (50-60 Hz) / DC operation 110-127 V UC Auxiliary contacts 2 NO + 2 NC 3-pole, Size S6 Busbar connections Drive: conventional screw terminal

Application:

Electromagnetic compatibility (EMC)

The 3RT contactors fulfill the requirements for environment category A.

Note:

When the contactors are used in an environment with frequency converters, the configuration notes in the Manual "SIRIUS – SIRIUS 3RT Contactors/Contactor Assemblies" must be observed,

Short-circuit protection
For short-circuit protection of the contactors without overload relay

Refer to the manuals for details of short-circuit protection of the contactors with overload relays

Selection guides are available for the fuseless assembly of motor feeders consisting of a 3RV2 motor starter protector and a 3RT2 contactor,

For the dimensioning of load feeders,

Motor protection

3RT2 contactors

3RU2 thermal overload relays or 3RB3 electronic overload relays can be fitted to the 3RT2 contactors for protection against overload.

3RT1 contactors

3RB2 electronic overload relays can be fitted to the 3RT1 contactors for protection against overload.

Plant and application monitoring

3RR2 monitoring relays can be fitted to the 3RT2 contactors for monitoring and measuring in the application.

Ratings of three-phase motors

The quoted rating (in kW) refers to the output power on the motor shaft (according to the nameplate).

The power rating specifications of the contactors in kW (in accordance with IEC 60947-4-1, Table G) are guide values for 4-pole standard motors at 50 Hz AC and specified voltage (e.g. 400 V AC). The actual starting and rated data of the motor to be switched must be considered when selecting the units. The motor current, motor protection device and the permissible contactor current acc. to the utilization category must be aligned with each other


3RT contactors, sizes S00 to S12


Our power range:

  • Contactors for switching motors:
    • Size S00: 3RT201 up to 7.5 kW
    • Size S0: 3RT202 up to 18.5 kW
    • Size S2: 3RT203 up to 37 kW
    • Size S3: 3RT204 up to 55 kW
    • Sizes S6 to S12: 3RT10 up to 250 kW
    • Sizes S10 and S12: 3RT12 up to 250 kW
    • Size 14: 3TF6 up to 450 kW
Standards

IEC/EN 60947‑1,
IEC/EN 60947‑4‑1,
IEC/EN 60947‑5‑1 (auxiliary switches)


Technical data

Product brand nameSIRIUS
Product designationPower contactor
Product type designation3RT1
General technical data
Size of contactorS6
Product extension
● function module for communicationNo
● Auxiliary switchYes
Surge voltage resistance
● of main circuit rated value8 kV
● of auxiliary circuit rated value6 kV
maximum permissible voltage for safe isolation
● between coil and main contacts acc. to EN 60947-1690 V
Protection class IP
● on the frontIP00; IP20 on the front with cover / box terminal
● of the terminalIP00
Shock resistance at rectangular impulse
● at AC8,5g / 5 ms, 4,2g / 10 ms
● at DC8,5g / 5 ms, 4,2g / 10 ms
Shock resistance with sine pulse
● at AC13,4g / 5 ms, 6,5g / 10 ms
● at DC13,4g / 5 ms, 6,5g / 10 ms
Mechanical service life (switching cycles)
● of contactor typical10 000 000
● of the contactor with added electronics-compatible auxiliary switch block typical5 000 000
● of the contactor with added auxiliary switch block typical10 000 000
Reference code acc. to DIN 40719 extended according to IEC 204-2 acc. to IEC 750K
Reference code acc. to DIN EN 81346-2Q
Ambient conditions
Installation altitude at height above sea level
● maximum2 000 m
Ambient temperature
● during operation-25 ... +60 °C
● during storage-55 ... +80 °C
Main circuit
Number of poles for main current circuit3
Number of NO contacts for main contacts3
Operating voltage
● at AC-3 rated value maximum1 000 V
Operating current
● at AC-1 at 400 V
— at ambient temperature 40 °C rated value215 A
● at AC-1
— up to 690 V at ambient temperature 40 °C rated value215 A
— up to 690 V at ambient temperature 60 °C rated value185 A
— up to 1000 V at ambient temperature 40 °C rated value100 A
— up to 1000 V at ambient temperature 60 °C rated value100 A
● at AC-2 at 400 V rated value185 A
● at AC-3
— at 400 V rated value185 A
— at 500 V rated value185 A
— at 690 V rated value170 A
— at 1000 V rated value65 A
● at AC-4 at 400 V rated value160 A
Connectable conductor cross-section in main circuit at AC-1
● at 60 °C minimum permissible95 mm²
● at 40 °C minimum permissible95 mm²
Operating current for approx. 200000 operating cycles at AC-4
● at 400 V rated value81 A
● at 690 V rated value65 A
Operating current
● at 1 current path at DC-1
— at 24 V rated value160 A
— at 110 V rated value18 A
— at 220 V rated value3.4 A
— at 440 V rated value0.8 A
— at 600 V rated value0.5 A
● with 2 current paths in series at DC-1
— at 24 V rated value160 A
— at 110 V rated value160 A
— at 220 V rated value20 A
— at 440 V rated value3.2 A
— at 600 V rated value1.6 A
● with 3 current paths in series at DC-1
— at 24 V rated value160 A
— at 110 V rated value160 A
— at 220 V rated value160 A
— at 440 V rated value11.5 A
— at 600 V rated value4 A
Operating current
● at 1 current path at DC-3 at DC-5
— at 24 V rated value160 A
— at 110 V rated value2.5 A
— at 220 V rated value0.6 A
— at 440 V rated value0.17 A
— at 600 V rated value0.12 A
● with 2 current paths in series at DC-3 at DC-5
— at 24 V rated value160 A
— at 110 V rated value160 A
— at 220 V rated value2.5 A
— at 440 V rated value0.65 A
— at 600 V rated value0.37 A
● with 3 current paths in series at DC-3 at DC-5
— at 24 V rated value160 A
— at 110 V rated value160 A
— at 220 V rated value160 A
— at 440 V rated value1.4 A
— at 600 V rated value0.75 A
Operating power
● at AC-1
— at 230 V at 60 °C rated value70 kW
— at 400 V rated value121 kW
— at 400 V at 60 °C rated value121 kW
— at 690 V rated value210 kW
— at 690 V at 60 °C rated value210 kW
— at 1000 V at 60 °C rated value165 kW
● at AC-2 at 400 V rated value90 kW
● at AC-3
— at 230 V rated value61 kW
— at 400 V rated value90 kW
— at 500 V rated value132 kW
— at 690 V rated value160 kW
— at 1000 V rated value90 kW
Operating power for approx. 200000 operating cycles at AC-4
● at 400 V rated value45 kW
● at 690 V rated value65 kW
Thermal short-time current limited to 10 s1 480 A
Power loss [W] at AC-3 at 400 V for rated value of the operating current per conductor13 W
No-load switching frequency
● at AC2 000 1/h
● at DC2 000 1/h
Operating frequency
● at AC-1 maximum800 1/h
● at AC-2 maximum300 1/h
● at AC-3 maximum750 1/h
● at AC-4 maximum130 1/h
Control circuit/ Control
Type of voltage of the control supply voltageAC/DC
Control supply voltage at AC
● at 50 Hz rated value110 ... 127 V
● at 60 Hz rated value110 ... 127 V
Control supply voltage at DC
● rated value110 ... 127 V
Operating range factor control supply voltage rated value of magnet coil at DC
● initial value0.8
● Full-scale value1.1
Operating range factor control supply voltage rated value of magnet coil at AC
● at 50 Hz0.8 ... 1.1
● at 60 Hz0.8 ... 1.1
Design of the surge suppressorwith varistor
Apparent pick-up power of magnet coil at AC
● at 50 Hz300 V·A

3RT1056-6AF36  Motor Contactor / 185A  Power Contactor Up To 250KW

Company Profile

Yueqing Richuang Automation Equipment Co.,Ltd

Yueqing Richuang Automation Equipment Co.,Ltd founded in 2011, position as the sourcing specialist of industrial parts & equipment. Our Business model are tailored for manufacturers, end users and seller to order their Maintenance, Repairing and Operating goods.

 

We're specializes in distributing and selling of well-know automation products, which includes Programmable Logic Controllers (PLC), Low-voltage Controland Distribution products, Industrial testing equipment,frequency Inverters, Servo system,Sofeware, etc. Our Brands include Schneider, ,ABB, Sick,Mitsubishi, Omron,IFM, Fluke, and many other Automation Equipment factories and suppliers.

 

As a group of companies,  We try to provide wisdom, individual product solution.We are fully responsible all of our products. Focus to before-after sales service, consult, quality guarantee, training base on customer benefit and satisfy. With abundant stock and years of exporting experience, we are looking forward to receiving your inquiry list!

 

 

 

Send your message to this supplier
*From:
Your email address is incorrect!
*To:

Yueqing Richuang Automation Equipment Co.,Ltd

*Subject:
Your subject must be between 10-255 characters!
*Message:
Your message must be between 20-3,000 characters!
Characters Remaining : (0/3000)

You May Like

China Schneider LC1-F400 Electrical Contactor Switch LC1F400 For Motor Control wholesale

Schneider LC1-F400 Electrical Contactor Switch LC1F400 For Motor Control

China A300-30-11 Three Phrase ABB DC Contactor / A Series ABB Magnetic Contactor wholesale

A300-30-11 Three Phrase ABB DC Contactor / A Series ABB Magnetic Contactor

China 3RT1054-6AP36 115 A 55 KW 2no 2nc Contactor Auxiliary Switch wholesale

3RT1054-6AP36 115 A 55 KW 2no 2nc Contactor Auxiliary Switch

China  Sirius 3rt1065-6ap36 265A Electrical Contactor Switch wholesale

Sirius 3rt1065-6ap36 265A Electrical Contactor Switch

China AF260-30 3 Phase ABB Af Contactors , ABB A Series Contactor 100-250V AC/DC wholesale

AF260-30 3 Phase ABB Af Contactors , ABB A Series Contactor 100-250V AC/DC

China Schneider TeSys LC1-D Series Ac Electrical Contactor Switch LC1-D09 To LC1-D95 wholesale

Schneider TeSys LC1-D Series Ac Electrical Contactor Switch LC1-D09 To LC1-D95

China LC1-F Series Schneider Ac Contactor , Schneider Electric Contactor 115 A To 2600 A wholesale

LC1-F Series Schneider Ac Contactor , Schneider Electric Contactor 115 A To 2600 A

China Schneider TeSys LC1-K Electrical Contactor Switch For Simple Control Systems wholesale

Schneider TeSys LC1-K Electrical Contactor Switch For Simple Control Systems

China SIRIUS 3RT  Electrical Contactors / 3 Poles  DC Contactor wholesale

SIRIUS 3RT Electrical Contactors / 3 Poles DC Contactor

China  SIRIUS 3RT1 Electrical Contactor Switch 3RT101 102 103 104 3 Pole wholesale

SIRIUS 3RT1 Electrical Contactor Switch 3RT101 102 103 104 3 Pole

China 3RT1055-6AF36 150A 75kw Electrical Contactor Switch wholesale

3RT1055-6AF36 150A 75kw Electrical Contactor Switch

Inquiry Cart 0