(1) According to the special requirements of users on site, in the agreement the technical standards of AC440-500KVA-RL Resistive Inductive Load Bank (hereinafter referred to as "system") and its accessories are proposed including their function, performance, usage, structure, installation and test to provide users with a high efficient and reliable choice, in order to meet the need for generator load test.
(2) The system consists of 1 sets of 500KVA Load Bank, The resistive power is 400kW, the inductive power is 300KVAR. The system is made up of two parts of measurement & control and load, mainly including the medium voltage dry type AC load bank, automatic data acquisition system, automatically loading and unloading control system, the cooling device, auxiliary control, remote control box and PC software and so on.
(3) This system, which is of independent research and development of electricity load test equipment by our technology, combining high voltage dry type load module with the automatic measurement and control module, with excellent insulation protection performance, it can detect generator output power and load capacity, full load and overload test.
The system can be used with a computer to realize the intelligent control, automatically completing the special test to all electrical parameters of generating set and generating tables, graphs, and supporting the print, release from the cumbersome manual operation to provide scientific and efficient detection means for the large power high voltage generating sets.
Applications
1 System can load power in rated range, measure generator steady-state 3 phase voltage, current, active power, power factor, frequency, and running time, and simulate the generator set real load working state. Power input using sectional type, energy dissipation type load, forced-air cooling, 3 phase fan decentralized supply air, air-flow is sufficient and low noise.
2 System can work with PC software to realize intelligent operation, automatically finish the parameters testing, and create testing data table, curves and reports that can be printed, reduce a lot of manual operation.
Technical Specifications
System Parameter | |
Rating voltage/frequency | 440V, 3 phase 4 wire 50Hz |
Max Load Power | Apparent Power: 500KVA Resistive Load: 400KW Inductive Load: 300KVAR |
Load Resolution | Resistive Load: 10 steps 1kW,2kW,2kW,5kW,10kW,10kW,20kW,50kW,100kW,200kW Inductive Load: 10 steps 1KVAR,2 KVAR, 2KVAR, 5KVAR, 10KVAR, 10KVAR, 20KVAR, 50KVAR, 100KVAR,100KVAR |
Power Factor | 0.8(lag) |
Load Tolerance (each step) | ±5% |
Load Tolerance (overall) | ±3% |
Fan &Control Voltage | External AC 3 phase 4 line, 380V/50Hz |
Wire Connection | Load bank input——Copper bar (star coupling ”Y”) Control power input——Connector-bar |
Communication Interface | RS485,RS232 |
Insulation | F |
Max Protection Grade | IP54 |
Duty Cycle | Continuous |
Cooling | Forced air cooling, by Axial Fan; horizontal inlet air, vertical exhaust cooling |
Enclosure | Container type,with a ladder, air inlet and outlet with mesh enclosure and protection door |
Internal Lighting | Adequate internal lighting will be provided |
Transportation | Hoisting, there are lifting lug in top of casing |
Color | Grey RAL7035 or as required |
Dimensions | 1550mm×1250mm×1680mm(L×W×H) |
Operating Environment Parameter | |
Workplace | Outdoor |
Ambient Temperature | -10℃~+50℃ |
Relative Humidity | ≤95% |
Atmospheric Pressure | 86~106kPa |
Comprehensive Protection Function: multiple protection, like over temperature, smoke. When in danger, automatically terminate the test and give alarm to protect safety of personnel and equipment.
Stable Running: with the latest generation control module as the core, a sharp rise in system response speed and anti-interference performance, avoid function failure in complex electrical environment, and ensure system running stably and reliably.
New Load Bank Technology: using the international advanced AC load bank technology, overcome the old water bank defects, such as bear bumpy, unable to use when go to sea, realize Mooring Trial and Sea Trail, and simulate the real working condition of generator running.
Mature Manufacturing Technology: load element using excellent anti-corrosion materials; waterproof insulation container packaging, suitable for adverse environment such as ocean. Internal layout is reasonable, air channel is clear, rapid heat emission, and satisfy continuous working need.
Accurate Data: with high precision data collection module and measuring meter, related equipment has passed the certification by CMA (China Metrology Accreditation) qualification testing institution, and ensures the reliability of data.
Flexible Control Mode: based on different using habit, several control modes as following can be choose, local panel operation, remote box controlling, and intelligent software.
Intelligent Loading: after setting generator rated power in software, system realize rapid loading through preset proportion, automatically and continuously load multiple power value and common tests, like stepping, full load, and over load, so that improve working efficiency.
High Efficiency Data Management: display real-time testing data, generate curves graphs automatically, also can put data into storage. According to generator set No. set up testing file, support to query at any time, and improve data management efficiency.
Hebei Kaixiang Electrical Technology Co., Ltd
Kaixiang intelligent power detection technology is the Chinese industry leader dedicated to providing load testing and maintenance of all types of power, to avoid accidents and economic losses due to power failure. As a national high-tech enterprises, science and technology to create the industry's first Kaixiang municipal enterprise technology center, with the establishment of China's oldest and largest intelligent power detection equipment R & D center and production base, creating the first brand of Chinese power detection "KAIXIANG Load. "
Kaixiang Technology was established in 1994, long-term focus on smart power detection technology development and application in shipbuilding, petroleum, offshore platforms, data centers, communications, power, military, aviation, research institutes and other areas, and in strict accordance with the ISO9001 international quality standard management system for the design, manufacture and service. The company's core technologies are independent research, has seven patents, 10 software copyrights, two corporate standards.Among them, Kaixiang "smart power marine generators AC load," Science and Technology Department of Hebei Province has been named the international advanced level scientific and technological achievements, the enterprise standard "dry AC load" to upgrade the industry standard by the Ministry of publicity.
Kaixiang Technology specializes in generators Intelligent Test System, HV / MV dry load, intermediate load military, RLC load, RCD nonlinear loads, renewable energy detection, smart grid - the development of micro-Grid testing and manufacturing equipment . Products have been widely used in the Jiangnan Shipyard, Huangpu Shipyard, Hudong Shipyard, CNOOC, Shengli Oilfield, CICC, Taikang Life, China Mobile, CNR, Beijing Electric Power, Beijing Institute of Technology, and other famous enterprises, institutions, but also exports to the United Kingdom, Japan, Korea, Australia, Singapore, Thailand and other overseas markets. Currently, there are over 20,000 units KaiXiang load in a well-functioning home and abroad.
KaiXiang load can be applied in shipbuilding, petroleum, offshore platforms, data centers, communications networks, financial, military, weapons, mobile power station, power plant security, mass transit, aviation, aerospace, renewable energy, smart grid - micro-grid, the instrument switches , research and teaching as well as electric vehicle charging management and other fields. Can provide users with the design, manufacture, installation, commissioning, training, maintenance of full service, as well as OEM, leasing and on-site testing services.
Kaixiang Technology at Keppel Shipyard in 2006 developed a sense of one-2926kVA resistance load is the first high-power marine dry AC load;
2009 was developed by the Huangpu Shipyard AC690V-14700K generators Intelligent Test System was the country's largest marine generator set capacity testing equipment;
2009 Zhejiang company developed high-power high-voltage AC load AC10.5kV-1760kW is China's first direct test of high-power high-voltage generators dry load;
Jiangnan Shipyard in 2010 developed AC390-12088K generators Intelligent Test System is a dry load on marine naval initial application.
Kaixiang technology to "quality-oriented, customer first" purpose, "professionalism, objectivity, innovation, efficiency" as a concept. Through our efforts, aimed at creating more value for users. We sincerely hope to cooperate with all walks of life friends, co-guardian of electrical safety, to make life better!