Omron PLC Relay Module JR-8L1 DIN Rail Mounting Isolation Each Relay Channel
PLC output circuit is generally divided into: relay output, transistor output and thyristor output three. Understanding the differences between these three output forms is very necessary for the hardware design of the PLC.
Transistor output circuit
The transistor output circuit is faster than the relay output (usually less than 0.2ms) and is suitable for applications requiring fast response. Since the transistor has no mechanical contacts, it has a longer life than the relay output circuit.
The external power supply of the transistor output circuit can only be a direct power supply, which is one aspect of its application limitations. In addition, the transistor output drive capability is less than the relay output, allowing the load voltage is generally DC5V ~ 30V, allowing the load current is 0.2A ~ 0.5A. These two points should be taken care of when using transistor output circuit types.
There are two main types of transistor output circuits: NPN and PNP open collector outputs.
PLC relay output circuit type allows the load is generally AC250V/50V, load current up to 2A, capacity up to 80 ~ 100VA (voltage × current), therefore, the PLC output is generally not directly driven high-current load (usually through a small load To drive a large load, such as the PLC output can be connected to a relatively small current relay, and then by the intermediate relay contacts to drive large loads, such as contactor coils, etc.).
PLC Relay Output Circuit Form Relay contact life is also limited (usually hundreds of thousands of times, depending on the load, such as the connection of inductive load life than the resistive load). In addition, the response time of the relay output is also slow (about 10ms). Therefore, it is not suitable to use this kind of circuit output form when the fast response is required (you can use the two output formats described below depending on the occasion).
When connecting an inductive load, in order to extend the service life of the relay contact, for the case of an external DC power supply, an overvoltage suppression diode should normally be applied across the load (a diode in the external relay coil as shown above and in the diagram); For load, an RC suppressor should be added to both ends of the load.
♦ Features
-- Standard DIN rain mounted
-- Status indication for each input
-- Special circuit for self anti-interference
-- Isolation for each relay channel
-- with relay base, easy to replace
♦ Typical Applications
• Micro-controller • PLC control • Servo System
• Electro-magnetic valve • DC Motors
• Home intelligent control
♦ Technical date
Model | JR-8L1/24VDC |
Output type | OMRON Relay |
I/O points | 8 |
Input signal | NPN and PNP compatible |
Input voltage | DC24V * DC5V,DC12V,AC110V,AC220V can be customized. |
Output voltage | AC/DC 0-250V |
Output Contacts | 1CO(SPDT) |
Contact capacity(resistive) | 10A 250VAC |
Operation voltage/Release voltage | ≥75%Un/≤10%Un |
Operation time/Release time | ≤15ms/≤8ms |
Switching frequency | 0.1Hz |
Dimensions(WxH) | 87×63mm |
Mounting | DIN rail |
Wenzhou Ginri Power Automation Co., Ltd.
GINRI POWER AUTOMATION CO.,LTD. is a professional production voltage phase sequence protection
device (and name: three-phase power monitor), and PLC output zoom
Board, and smart type motor integrated protection device, and
industrial parts manufacturers, technology development team in
elevator industry, and refrigeration industry, and crane industry,
environmental equipment, mechanical NC industry and the industrial
following insurance industry, field has more than 10 years practice
experience, has development out variety price economic and function
excellent of products. CQC product quality system by China Quality
Centre (3C) certification and CE certification, products in the
manufacturing process in strict accordance with the ISO9001 quality
assurance system requirements and professional technical and
service support.
Voltage phase-sequence protection for many years (equipment,
refrigeration equipment, crane (passenger and goods) elevators,
control of DC power supply system (Cabinet) screens, precision air
conditioners, room air conditioners, electric hoist, boiler
equipment, laser equipment, parking equipment, cranes, compressors)
and so on using the run.
PLC output amplifiers (environmental protection equipment,
numerical control and automation equipment, automobile, plastic
machinery, hydraulic machinery, ceramic foam machinery, woodworking
machinery, machinery) and so on using the run.
Years of integrated Intelligent motor protector (power plants,
paper mills, steel mills, aluminium plants, cement plants, sewage
treatment plants, coal preparation plants, refineries,
petrochemical plants), and so on using the run.
Product quality is stable and safe, reliable, and earned a solid
market position in the market and a high reputation in the
industry, received unanimous recognition and praise of our
customers.
Ginri company always adhere to "scientific management as the core,
the user needs for the Centre to focus on product quality,
meticulous service is sincere," the spirit of enterprise, please
call us from all walks of life, thank you!