Home /

16 Way PLC SCR Module Control Board Release Overload Anti - Interference Circuit

Send your message to this supplier
*From:
Your email address is incorrect!
To:Wenzhou Ginri Power Automation Co., Ltd.
*Subject:
Your subject must be between 10-255 characters!
*Message:
Your message must be between 20-3,000 characters!
Yes!I would like your verified suppliers matching service!
Buy cheap 16 Way PLC SCR Module Control Board Release Overload Anti - Interference Circuit from wholesalers
  • Buy cheap 16 Way PLC SCR Module Control Board Release Overload Anti - Interference Circuit from wholesalers
  • Buy cheap 16 Way PLC SCR Module Control Board Release Overload Anti - Interference Circuit from wholesalers

16 Way PLC SCR Module Control Board Release Overload Anti - Interference Circuit

Ask Latest Price
Brand Name:GINRI
Model Number:JR-16K
Certification:CE,CCC
Payment Terms:L/C, T/T, Western Union,Paypal
Supply Ability:20000Pcs per month
Delivery Time:1-30 days upon order quantity
Company Data
Active Member
Business Type: 86-577-6298-2267
Business Type: Manufacturer
Officials: No.337,Kaichuang Road,Baitawang Industrial Distrit, Beibaixiang Town,Yueqing City,Zhejiang Province,China
Quality: Quality Certifitation Available
Product Details Company Profile
Product Details

16 Way PLC SCR Module Control Board Release Overload Anti - Interference Circuit


PLC's three output types are: relay output, transistor output and thyristor output. What are the differences between these three different output types?

(1) Relay output:

The advantage is that different common points can have different AC and DC loads, and the voltages can also be different. The load current can reach 2A/point; however, the relay output method is not suitable for high-frequency operation load, which is the life of the relay. decided. Its life is reduced with the increase of load current, generally in the hundreds of thousands of times to Jl million times, some company products can reach more than 10 million times, the response time is 10ms.

(2) Thyristor output:

With a load capacity of 0.2A/point, only with AC load, can adapt to high frequency operation, response time is 1ms.

(3) Transistor output:

The biggest advantage is to adapt to high-frequency operation, the response time is short, generally about 0.2ms, but it can only take a DC5-30V load, the maximum output load current is 0.5A/point, but every 4 points can not be greater than 0.8A.

When your system output frequency is less than 6 times per minute, relay output should be preferred because of its simple circuit design, strong anti-jamming and load carrying capacity. When the frequency is 10 times/min or less, the relay output mode can be adopted; the Darlington transistor (5-10A) can also be driven by the PLC output, and then the load can be driven, which can be greatly reduced.

Relay advantages: AC and DC load can be driven; load rated current is large;

Disadvantages: the operating frequency can not be too high, while the relay has a long life, usually 1 million times;

Transistor advantages: the operating frequency can reach several hundred KHZ, non-contact, so there is no statement of mechanical life;

Disadvantages: Can only be connected to DC load (generally less than DC30V), the current is relatively small;

Triac (Thyristor Output): Can only be connected to AC load, high operating frequency, long life, but the rated current of the load is also small

Transistors are mainly used for positioning control. The output of the crystal is used to emit pulses. The relay cannot be pulsed and it cannot be positioned. If the relay is used to control the positioning servo or stepping, the positioning module must be added, which is not economical. With a single transistor output, servos can be controlled. That's it. According to the production process requirements, the start and stop of various indicator lights, frequency converters/digital DC governors should adopt transistor output, which is suitable for high frequency operation and short response time; if the PLC system output frequency is less than 6 times per minute, The relay output should be the first choice. With this method, the output circuit is simple in design and has strong anti-interference and load carrying capacity.

1. Different load voltage and current types

Load type: Transistors can only carry DC loads, while relays can have both AC and DC loads.

Current: Transistor Current 0.2A-0.3A, Relay 2A.

Voltage: The transistor can be connected to 24V DC (generally the maximum is about 30V DC, and the relay can be connected to DC 24V or AC 220V.

2. Different load capacities

The ability of a transistor to carry a load is less than the ability of a relay to carry a load. When using a transistor, it is sometimes necessary to add other things to drive large loads (such as relays, solid state relays, etc.).

3. Transistor overload capacity is less than the overload of the relay

In general, when there is a large inrush current (for example, light bulbs, inductive loads, etc.), the transistor has less overload capacity and needs to be derated more.

4. Transistors respond faster than relays

The principle of relay output type is that the CPU drives the relay coil to make the contacts pull in and make the external power supply drive the external load through the closed contacts. The open circuit leakage current is zero and the response time is slow (about 10ms).

Transistor output type principle is the CPU through the optical coupling to make the transistor off, to control the external DC load, the response time is fast (about 0.2ms or even less). Transistor output is generally used for high-speed output, such as servo/stepping, etc., for output with high operating frequency: such as temperature PID control, mainly used in stepping motor control, servo control, and solenoid valve control (high valve operating frequency ).

5. In the rated working condition, the relay has life cycle times, and the transistor has only aging and no limit on the number of uses.

Because the relay is a mechanical component, it has a long operating life. The transistor is an electronic component. Only the aging is used, and the number of uses is not limited. The number of switches per minute of the relay is also limited, while the transistor is not.

6. The transistor output is slightly more expensive.


♦ Features

-- Standard DIN rain mounted

-- Status indication for each input

-- Special circuit for self test, overload, short-circuit and anti-interference

-- High quality SCR components with low on-resistance and excellent stability


♦ Typical Applications

• Micro-controller • PLC control • Servo System

• Electro-magnetic valve • DC Motors

• Home intelligent control

♦ Technical data


ModelJR-xK
Output typeSCR
I/O points4,6,8,12,16
Input signalNPN/PNP
Input voltageDC24V
Output voltageAC 24-250V
Output Contacts1NO
Contact capacity(resistive)3.15A 250VAC
Operation voltage/Release voltage>5VDC/<1.5VDC
Operation time/Release time<10ms/<10ms
Switching frequency≥5kHz
Dimensions(WxH)87×46mm
MountingDIN rail

16 Way PLC SCR Module Control Board Release Overload Anti - Interference Circuit

Company Profile

Wenzhou Ginri Power Automation Co., Ltd.

GINRI POWER AUTOMATION CO.,LTD. is a professional production voltage phase sequence protection device (and name: three-phase power monitor), and PLC output zoom Board, and smart type motor integrated protection device, and industrial parts manufacturers, technology development team in elevator industry, and refrigeration industry, and crane industry, environmental equipment, mechanical NC industry and the industrial following insurance industry, field has more than 10 years practice experience, has development out variety price economic and function excellent of products. CQC product quality system by China Quality Centre (3C) certification and CE certification, products in the manufacturing process in strict accordance with the ISO9001 quality assurance system requirements and professional technical and service support.

Voltage phase-sequence protection for many years (equipment, refrigeration equipment, crane (passenger and goods) elevators, control of DC power supply system (Cabinet) screens, precision air conditioners, room air conditioners, electric hoist, boiler equipment, laser equipment, parking equipment, cranes, compressors) and so on using the run.

PLC output amplifiers (environmental protection equipment, numerical control and automation equipment, automobile, plastic machinery, hydraulic machinery, ceramic foam machinery, woodworking machinery, machinery) and so on using the run.

Years of integrated Intelligent motor protector (power plants, paper mills, steel mills, aluminium plants, cement plants, sewage treatment plants, coal preparation plants, refineries, petrochemical plants), and so on using the run.

Product quality is stable and safe, reliable, and earned a solid market position in the market and a high reputation in the industry, received unanimous recognition and praise of our customers.

Ginri company always adhere to "scientific management as the core, the user needs for the Centre to focus on product quality, meticulous service is sincere," the spirit of enterprise, please call us from all walks of life, thank you!

Send your message to this supplier
*From:
Your email address is incorrect!
*To:

Wenzhou Ginri Power Automation Co., Ltd.

*Subject:
Your subject must be between 10-255 characters!
*Message:
Your message must be between 20-3,000 characters!
Characters Remaining : (0/3000)

You May Like

China PLC SCR I O Relay Module 12K Excellent Stability Status Indication For Each Input wholesale

PLC SCR I O Relay Module 12K Excellent Stability Status Indication For Each Input

China PLC 8 Channel Relay Module / Silicon Controlled Module 3.15A DC24V Low On - Resistance wholesale

PLC 8 Channel Relay Module / Silicon Controlled Module 3.15A DC24V Low On - Resistance

China Power PLC SCR Module PLC Silicon Controlled Rectifier DIN Rail Mounting JR-XK wholesale

Power PLC SCR Module PLC Silicon Controlled Rectifier DIN Rail Mounting JR-XK

China 6CH PLC Amplifier Board Module / SCR Output Board DIN Slider Servo System wholesale

6CH PLC Amplifier Board Module / SCR Output Board DIN Slider Servo System

China Motors PLC SCR Module , AC Solenoid Valve Driver Board SCR Zero Trigger Solid State wholesale

Motors PLC SCR Module , AC Solenoid Valve Driver Board SCR Zero Trigger Solid State

China 4 Channel Relay Module / PLC Amplifier Board  Positive Negative Control Optocoupler wholesale

4 Channel Relay Module / PLC Amplifier Board Positive Negative Control Optocoupler

China 8 Channel Electronic PLC SCR Module Fit PLC Outputs 24VDC Inputs , 250VAC Outputs wholesale

8 Channel Electronic PLC SCR Module Fit PLC Outputs 24VDC Inputs , 250VAC Outputs

China AC Amplifier Board Din Rail Relay Module 1NO Output Contactor Short - Circuit wholesale

AC Amplifier Board Din Rail Relay Module 1NO Output Contactor Short - Circuit

China DC24V PLC SCR Module Output Amplified Module PLC PNP NPN Control Board wholesale

DC24V PLC SCR Module Output Amplified Module PLC PNP NPN Control Board

China DC24V PLC SCR Module Output Amplified Module PLC PNP NPN Control Board wholesale

DC24V PLC SCR Module Output Amplified Module PLC PNP NPN Control Board

China PLC SCR I O Relay Module 12K Excellent Stability Status Indication For Each Input wholesale

PLC SCR I O Relay Module 12K Excellent Stability Status Indication For Each Input

Inquiry Cart 0